About pH

Basic principle of the electrode
    Potential analysis method used in the electrode is called a galvanic cell. Primary battery is a system, its role is to make the chemical energy into electricity. The battery voltage is called the electromotive force (EMF). The electromotive force (EMF) consists of two half cell. One and a half cells called measuring electrode, and its potential is associated with specific ion activity; Another one and a half in reference battery, often referred to as the reference electrode, it is general and measuring solution are interlinked, and connected to the measuring instrument.
    For example, an electrode formed a thong in the salt solution of silver ions in a silver conductor is made, at the interface between conductor and solution, because the metal salt solution and two phase different activity of silver ion, it forms ions of charging process, and form a certain potential difference. Lose electronic silver ions into the solution. When there is no reverse charge the current stage, that is not current, a process that will eventually reach a balance. In this state of equilibrium voltage is called the half cell potential or existing in the electrode potential.
    This (as above) is composed of metal and solution containing this metal ion electrode is called the first kind of electrode.
    The measurement of this potential is relatively a potential has nothing to do with the composition of the salt solution of reference electrode. The reference electrode with independent potential is also known as the second electrode. For such electrodes, metal wires are covered a layer of the metal micro soluble salt (such as: Ag/AgCl), and inserts in electrolyte solution containing this kind of metal salt anions. The half cell potential or the size of the electrode potential depends on the activity of the anion.
The voltage between two electrodes follow the NERNST (NERNST formula:


Type: E - potential
E0 standard voltage, electrode
R - gas constant (8.31439 joules/Moore and ℃)
T - kelvin's absolute temperature (20 ℃ = 273 example: + 293 degrees kelvin)
F - ferrari brother constant (96493 coulomb/equivalent)
N - measured ion valence (silver = 1, h = 1)
AMe - ion activity
    The standard hydrogen electrode is all potential measuring reference point. Standard hydrogen electrode is a platinum wire, use the method of electrolytic plating platinum chloride (coating), and surrounded by filling the hydrogen (fixed pressure 1013 hpa).
    The electrodes immersed in 25 ℃ H3O + ion content is 1 mol/l in the solution, it forms all half cell potential measurement refers in the electrochemical potential or electrode potential. The hydrogen electrode as reference electrode is difficult in practice, then use the second electrode as the reference electrode. One of the most commonly used is the silver/silver chloride electrode. The electrode by dissolving the AgCl react to changes of chlorine ion concentration.
    The reference electrode electrode potential through saturated KCL storage pool (such as: 3 mol/l KCL) to achieve a constant. In the form of a liquid or gel electrolyte solution through the diaphragm and connected test solution.
    Using the electrode combination - silver electrode and Ag/AgCl reference electrode can measure of silver ions content in the film flushing fluid. Can also be silver electrode for platinum or gold electrode of REDOX potential measurement. For example, some kind of metal ion oxidation phase.
    The most familiar is the most commonly used PH indicator electrode is glass electrode. It's a end on blown glass tube for pH sensitive glass membrane. Tube filling containing saturated AgCl 3 mol/l KCL buffer solution, the pH value of 7. Exists in glass membrane on the surface of the second reflecting the PH value of the potential difference in Ag/AgCl conduction system, such as the second electrode, the export.
    The potential difference also follow the nernst formula:

    E = 59.16 mv / 25 ℃ per pH
    Type of R and F is constant, n as the valence, each ion has its fixed values. For hydrogen ions, n = 1.
    "T" as a variable, temperature plays a significant role in the nernst formula. As temperatures rise, potential value will increase. For every 1 ℃ temperature change is big, will cause potential 0.2 mv/per pH changes.      With the pH value, per 1 ℃ were pH 0.0033 per 1 pH changes.
    That is to say: for about 20 ~ 30 ℃, and 7 ph measurement, do not need to compensate for temperature change; For temperature 30 ℃ > or < 20 ℃ and pH > 6 or 8 pH pH applications must compensate to temperature changes.
    Figure 1: pH - potential - the relationship between the ion concentration
    0   1   2  3   4   5  6  7  8  9  10  11  12  13  14       OH- ions
   14  13 12 11 10 9  8  7  6  5   4   3    2    1    0         H+ ion
    0   1   2   3   4  5  6  7  8  9  10  11  12  13  14        pH
` + 414.4 ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? +. 59.2 0-59.2,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 414.4 mv / 25 ℃

主站蜘蛛池模板: 亚洲精品aⅴ中文字幕乱码 亚洲精品 | 四房播播最新地址 | 精品视频无码一区二区三区 | 中文字幕免费播放 | 日本欧美熟妇色一本在线视 | 午夜性色一区二区三区不卡视频 | 精品成人一区二区三区电影 | 国产精品久久久久成人免费 | 丰满人妻熟妇乱又伦精品 | 午夜亚洲动漫精品AV网站 | 国产无遮挡裸体免费视频A片软件 | 红桃影院在线免费观看 | 久久影视手机免费观看 | 中文字幕欧美视频 | 丁香社区五月开心激情婷婷 | 成aⅴ人片在线观 | 国内精品A片XXX久久久 | 国产亚洲另类无码专区 | 国产成人AV天堂 | 久久久久久久久精品天堂无码免费 | 日本精品人妻无码久久久 | 亚洲精品国产一区二区贰佰信息网 | 亚洲av无码乱码在线观看裸奔 | 波多野吉衣免费一区 | 欧美日韩高清观看一区二区 | 精品一区二区三区四区在线播放 | 色婷婷小说网 | 久久99精品久久久久久噜噜 | 日本欧美一区二区三区在线 | 91大神精品长腿在线 | 欧美日本精品一区二区三区 | 国产美女丝袜高潮白浆 | av片日韩一区二区三区在线观看 | 亚洲 日韩 色 图网站 | 91福利国产在线观一区二区 | 色综合天天综合高清影视 | 国产成人亚洲综合无码 | mv字幕免费高清在线7字幕免费看2 | 国产精品原创巨作av女教师 | 精品国产区一区二区三区在线观 | 色网站视频|